A team led by researchers at the Third Military Medical University in Chongqing, China, has reported a glue-based system that joins blood vessels about 1 mm wide without stitches and carries a wireless sensor that uses artificial intelligence to watch for problems afterwards. The work, tested only in rats so far, was published in the journal Science on 12 November 2026 and drew wider attention through a Phys.org report on 28 November 2026.

What did the researchers build?

They built what they call an integrated microneedle-interlocking adhesive system, or iMAS, modelled on the way plant roots anchor themselves in soil. According to the paper's abstract on PubMed, it pairs a water-repelling polymer matrix with tiny four-armed, tetrahedral microneedles that lock into the vessel wall to create a firm, three-dimensional bond.

The Phys.org report describes the adhesive as silicone-based, able to push aside surface water and bond chemically with tissue, which lets it work in a wet, blood-filled surgical field. A temporary cuff holds the two vessel ends in line and keeps the glue out of the channel through which blood flows.

Why is joining small vessels so hard?

Stitching small-calibre vessels, a procedure called microvascular anastomosis, is technically demanding, slow and can fail because of complications such as clots, the authors write in the abstract. They add that existing surgical adhesives have performed poorly in this setting because the joint between two tiny vessels offers so little surface for bonding.

What did the rat experiments show?

In rat models, iMAS cut procedural time by 78% and suppressed neointimal hyperplasia, a thickening of the inner vessel wall that can narrow a repaired artery, the abstract says. Phys.org reported that average joining time fell from about 39 minutes with stitches to under nine minutes, with less bleeding and better preservation of the inner lining.

The embedded sensor is battery-free and is read by an external device. It registers each pulse through changes in its electrical response, and machine learning was used to pick out narrowed vessels from the signal. In a separate experiment, donor hearts connected to rats' neck vessels were monitored for three months, and the sensor signals helped distinguish failing grafts from working ones, with ultrasound used as a comparison.

What are the limits?

All the evidence so far comes from animals, and the system has not been tested in people. Phys.org noted that the authors say clinical validation is still needed, that reliability across different vessel sizes and surgical sites must be checked, and that it is not yet clear whether the sensor can warn early enough to save a failing repair. Some long-term comparisons involved only small groups of rats.

What happens next?

The researchers have suggested the approach could later be adapted for nerve repair, tendon attachment and sealing leaks around the brain or spinal cord. The full paper, by first author Fangchao Xue and colleagues, is available through Science.